Glossary
Print
Aperture
20 mm
Angle Transmitter of Galvanometer Scanners
analog position detector
Show Optical Configuration
Wavelength range
(standard)
Available standard coatings:
1064 nm
355 nm
10600 nm
Max. laser power
(standard systems, 100% duty cycle)
1000 W @ 1064 nm
Typical scan angle
±0.35 rad (optical)
Image field size
(1064 nm, f = 160 mm)
60 mm x 60 mm
Typical spot size
(1064 nm, f = 160 mm, M2 = 1.0)
16 µm
Show Dynamics
Number of installed tunings
1
Typical tuning
fast vector tuning
Tracking error
0.25 ms
Marking speed
(f = 160 mm)
1.1 m/s
Positioning speed
(f = 160 mm)
8 m/s
Writing speed
(with F-Theta lens, f = 160 mm)
High writing quality
210 cps
Good writing quality
290 cps
Step response time (fixed angle)
(in tolerance band ± 450 µrad)
10 mrad
0.58 ms
100 mrad
2.38 ms
Precision
Repeatability
(RMS)
< 2 µrad
Positioning resolution
(max.)*
16 Bit *
Nonlinearity
< 0.9 mrad / 44°
Temperature drift
Offset
< 30 µrad/K
Gain
< 160 ppm/K
8-h-drift
(after 30 min warm-up)
Offset
< 100 µrad
Gain
< 250 ppm
* 16 bit: based on the full angle range (e.g. positioning resolution 11 µrad for angle range ±0.36 rad)
Electronics / Control
Servo control galvanometer scanner
digital servo control board
Control interface
(alternatives)
digital SL2-100,
digital XY2-100 standard
Advanced diagnosis options
no
Power requirements
Available variants:
24 V DC, max. 2.6 A
30 V DC, max. 2.6 A
Mechanics
Scan axes
2-axis system
Housing variants
standard: scan head
Connector positions
beam entrance side
Weight without objective
(standard housing)
3.7 kg
Dimensions (L x W x H)
(standard housing)
(155 x 130 x 122) mm3
Other Provisions
Water cooling
no
Air cooling
no
Other Specifications
Operating temperature
25 °C ± 10 °C
Gain error
< 5 mrad
Zero offset deviation
< 5 mrad
Add-ons
Combinable with varioSCAN II for 3D applications,
control with SCANLAB´s RTC boards,
camera adapter
Typical Applications
Light welding and cutting applications, additive manufacturing
Compare Products