With Digital Encoder

intelliSCANse 14

Print
Aperture
14 mm
Angle Transmitter of Galvanometer Scanners
digital encoder
Show Optical Configuration
Wavelength range
(standard)
Standard coatings for all common laser systems:
YAG- & fiber lasers,
Green lasers,
UV lasers,
DUV lasers,
CO2 lasers

In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings
Max. laser power
(standard systems, 100% duty cycle)
440 W @ 1064 nm
Typical scan angle
±0.35 rad (opt.)
Image field size
(1064 nm, f = 160 mm)
95 mm x 95 mm
Typical spot size
(1064 nm, f = 160 mm, M2 = 1.0)
23 µm
Show Dynamics
Number of installed tunings
up to 3
Typical tuning
sharp edge tuning
Tracking error
0.15 ms
Marking speed
(f = 160 mm)
2.0 m/s
Positioning speed
(f = 160 mm)
5.0 m/s
Writing speed
(with F-Theta lens, f = 160 mm)
High writing quality
480 cps
Good writing quality
680 cps
Step response time
(settling to 1/1000 of full scale)
1% of full scale
0.45 ms
10% of full scale
3.0 ms
Precision
Repeatability
(RMS)
< 0.4 µrad
Positioning resolution
(max.)*
20 bit *
Nonlinearity
< 0.5 mrad / 44°
Temperature drift
偏移量
< 15 µrad/K
Gain
< 8 ppm/K
8-h-drift
(after 30 min warm-up)
Offset
< 20 µrad
Gain
< 20 ppm
24-h-drift
(after 3 h warm-up)
Offset
< 20 µrad
Gain
< 25 ppm
* 20 bit: based on the full angle range (e.g. positioning resolution 0.7 µrad for angle range ±0.36 rad),
resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
Electronics / Control
Servo control galvanometer scanner
digital servo control board
Control interface
(alternatives)
digital SL2-100,
digital XY2-100 Enhanced
Advanced diagnosis options
yes (iDRIVE)
Power requirements
Available variants:
30 V DC, max. 3 A
48 V DC, max. 3 A
Mechanics
Scan axes
2-axis system
Housing variants
standard: scan head
Connector positions
beam entrance side,
alternatively opposite to beam exit side
Weight without objective
(standard housing)
3 kg
Dimensions (L x W x H)
(standard housing)
(175 x 114 x 147) mm3
Beam displacement
16.42 mm
Other Provisions
Water cooling
optionally
Air cooling
optionally
Other Specifications
Operating temperature
25 °C ± 10 °C
Gain error
< 5 mrad
Zero offset deviation
< 5 mrad
Add-ons
Combinable with varioSCAN for 3D applications,
control with SCANLAB´s RTC boards,
camera adapter
Typical Applications
Microprocessing,
Microstructuring,
Materials processing,
Processing-on-the-fly
Compare Products
Application-Micromachining-Products

附加设备

Options

  • Objectives with optimized mounting kits
  • Light weight mirrors
  • Application- and customer-specific tunings

应用领域

更多问题

我们期待为您提供帮助!

电话 +49 89 800 746-0