| hurrySCAN III 14 | |||
| Aperture | 14 mm | ||
| Angle Transmitter of Galvanometer Scanners | analog position detector | ||
| Optical Configuration | |||
| Wavelength range (standard) | Standard coatings for all common laser systems: YAG- & fiber lasers, Green lasers, UV lasers, DUV lasers, CO2 lasers In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings | ||
| Max. laser power (standard systems, 100% duty cycle) | 440 W @ 1064 nm | ||
| Typical scan angle | ±0.35 rad (opt.) | ||
| Image field size (1064 nm, f = 160 mm) | 95 mm x 95 mm | ||
| Fiber adapter | no | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Dynamic | |||
| Number of installed tunings | 1 | ||
| Typical tuning | fast vector tuning | ||
| Tracking error | 0.18 ms | ||
| Marking speed (f = 160 mm) | 2.0 m/s | ||
| Positioning speed (f = 160 mm) | 12 m/s | ||
| Writing speed (with F-Theta objective, f = 160 mm) | |||
| High writing quality | 410 cps | ||
| Good writing quality | 660 cps | ||
| Step response (full angle) (settling to 1/1000 of full scale) | |||
| 1% of full scale | 0.35 ms | ||
| 10% of full scale | 1.2 ms | ||
| Step response (fixed angle) (in tolerance band ± 450 μrad) | |||
| 10 mrad | |||
| 100 mrad | |||
| Precision | |||
| Repeatability (RMS) | < 2 µrad | ||
| Positioning resolution (max.)* | 18 bit * | ||
| Nonlinearity | < 0.9 mrad / 44° | ||
| Temperature drift | |||
| Offset | < 15 µrad/K | ||
| Gain | < 25 ppm/K | ||
| 8 hour drift (after 30 min warm-up) | |||
| Offset | < 100 µrad | ||
| Gain | < 100 ppm | ||
| 24 hour drift (after 3 h warm-up) | |||
| Offset | < 100 µrad | ||
| Gain | < 100 ppm | ||
| 
              * 18 bit: based on the full angle range (e.g. positioning resolution 2.8 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
             | |||
| Electrics / Control | |||
| Servo control galvanometer scanner | analog servo control board | ||
| Control interface (alternatives) | digital SL2-100, digital XY2-100 standard, analog ±4.8 V, analog ±9.6 V | ||
| Advanced diagnosis options | no | ||
| Power requirements | ±(15+1.5) V DC, max. 3 A | ||
| Mechanics | |||
| Scan axes | 2-axis system | ||
| Housing variants | standard: scan head alternative: module (without housing) | ||
| Connector positions | beam entrance side, alternatively opposite to beam exit side | ||
| Dimensions (L x W x H) (standard housing) | (175 x 114 x 147) mm3 | ||
| Weight without objective (standard housing) | approx. 3 kg | ||
| Beam displacement | 16.42 mm | ||
| Other Provisions | |||
| Water cooling | optionally | ||
| Air cooling | optionally | ||
| Options | objectives with optimized mounting kits | ||
| Other Specifications | |||
| Dimensions (L x W x H) (standard housing) | (175 x 114 x 147) mm3 | ||
| Weight without objective (standard housing) | approx. 3 kg | ||
| Beam displacement | 16.42 mm | ||
| Operating temperature | |||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Skew | < 1.5 mrad | ||
| Step response time (settling to 1/1000 of full scale) | |||
| Typical Optical Configurations | |||
| Applications | |||
| Typical Applications | Materials processing, Marking, Microstructuring, Rapid Manufacturing, 3D applications, Processing-on-the-fly | ||