fiberSYS
Aperture 30 mm
Angle Transmitter
of Galvanometer Scanners
digital encoder
Optical Configuration
Wavelength range
(standard)
1060 - 1085 nm
Max. laser power
(standard systems, 100% duty cycle)
2000 W
depending on optical configuration
Typical scan angle ±0.37 rad (optical)
Image field size
(1064 nm, f = 160 mm)
Fiber adapter QBH/HLC-8 QD/LLK-D
Gain error < 5 mrad
Zero offset deviation < 5 mrad
Dynamic
Number of installed tunings 1
Typical tuning SCANahead
Tracking error 0 ms
Marking speed
(f = 160 mm)
43.0 m/s
(for f = 615 mm)
Positioning speed
(f = 160 mm)
43.0 m/s
(for f = 615 mm)
Writing speed
(with F-Theta objective, f = 160 mm)
High writing quality
Good writing quality
Step response (full angle)
(settling to 1/1000 of full scale)
1% of full scale 0.47 ms
10% of full scale 1.54 ms
Step response (fixed angle)
(in tolerance band ± 450 μrad)
10 mrad
100 mrad
Precision
Repeatability
(RMS)
< 0.4 µrad
Positioning resolution
(max.)*
20 bit *
Nonlinearity < 0.5 mrad / 44°
Temperature drift
Offset < 25 µrad/K
Gain < 8 ppm/K
8 hour drift
(after 30 min warm-up)
Offset < 30 µrad
Gain < 30 ppm
24 hour drift
(after 3 h warm-up)
Offset < 30 µrad
Gain < 30 ppm
* 20 bit: based on the full angle range (e.g. positioning resolution 0.7 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
Electrics / Control
Servo control galvanometer scanner digital servo control board
Control interface
(alternatives)
digital SL2-100
Advanced diagnosis options yes (iDRIVE)
Power requirements 48 V DC, max. 6 A
Mechanics
Scan axes 3-axis system
Housing variants scan head
Connector positions beam entrance side
Dimensions (L x W x H)
(standard housing)
(290 x 140 x 340) mm3
Weight without objective
(standard housing)
20 kg
Beam displacement 35.54 mm
Other Provisions
Water cooling yes
Air cooling no
Options Open Interface Extension (OIE),
additional monitoring port via beam splitter cube
Other Specifications
Dimensions (L x W x H)
(standard housing)
(290 x 140 x 340) mm3
Weight without objective
(standard housing)
20 kg
Beam displacement 35.54 mm
Operating temperature 25 °C ± 10 °C
Gain error < 5 mrad
Zero offset deviation < 5 mrad
Skew
Step response time
(settling to 1/1000 of full scale)
Typical Optical Configurations Custemers specific
Applications
Typical Applications Additive manufacturing,
Laser welding,
Electromobility,
3D applications