hurrySCAN 20
Aperture 20 mm
Angle Transmitter
of Galvanometer Scanners
analog position detector
Optical Configuration
Wavelength range
(standard)
Standard coatings for all common laser systems:
YAG- & fiber lasers,
Green lasers,
UV lasers,
CO2 lasers

In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings
Max. laser power
(standard systems, 100% duty cycle)
2000 W @ 1064 nm
with air cooling
Typical scan angle ±0.35 rad (opt.)
Image field size
(1064 nm, f = 160 mm)
60 mm x 60 mm
Fiber adapter no
Gain error < 5 mrad
Zero offset deviation < 5 mrad
Dynamic
Number of installed tunings 1
Typical tuning fast vector tuning
Tracking error 0.35 ms
Marking speed
(f = 160 mm)
1.0 m/s
(for f = 163 mm)
Positioning speed
(f = 160 mm)
6.0 m/s
(for f = 163 mm)
Writing speed
(with F-Theta objective, f = 160 mm)
High writing quality 210 cps
Good writing quality 320 cps
(for f = 163 mm)
Step response
(settling to 1/1000 of full scale)
1% of full scale 0.80 ms
10% of full scale 2.50 ms
Precision
Repeatability
(RMS)
< 2 µrad
Positioning resolution
(max.)*
18 bit *
Nonlinearity < 3.5 mrad / 44°
Temperature drift
건너뛰기
Gain
8 hour drift
(after 30 min warm-up)
건너뛰기
Gain
24 hour drift
(after 3 h warm-up)
건너뛰기
Gain
* 18 bit: based on the full angle range (e.g. positioning resolution 2.8 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
Electrics / Control
Servo control galvanometer scanner analog servo control board
Control interface
(alternatives)
digital SL2-100,
digital XY2-100 standard,
analog ±4.8 V,
analog ±9.6 V
Advanced diagnosis options no
Power requirements ±(15+1.5) V DC, max. 6 A
Mechanics
Scan axes 2-axis system
Housing variants standard: scan head
alternative: module (without housing)
Connector positions beam entrance side,
if applicable additionally opposite to beam exit side
Dimensions (L x W x H)
(standard housing)
(206.9 x 140 x 180) mm3
Weight without objective
(standard housing)
approx. 5.8 kg
Beam displacement 25.25 mm
Other Provisions
Water cooling yes
Air cooling yes
Options objectives with optimized mounting kits
Other Specifications
Dimensions (L x W x H)
(standard housing)
(206.9 x 140 x 180) mm3
Weight without objective
(standard housing)
approx. 5.8 kg
Beam displacement 25.25 mm
Operating temperature
Gain error < 5 mrad
Zero offset deviation < 5 mrad
Skew < 1.5 mrad
Step response time
(settling to 1/1000 of full scale)
Typical Optical Configurations
Applications
Typical Applications Materials processing,
Marking,
Microstructuring,
Rapid Manufacturing,
3D applications,
Processing-on-the-fly