| SCANcube III 14 | |||
| Aperture | 14 mm | ||
| 
                  Angle Transmitter of Galvanometer Scanners  | 
              analog position detector | ||
| Optical Configuration | |||
| 
                  Wavelength range (standard)  | 
              
            Standard coatings for all common laser systems:  YAG- & fiber lasers, Green lasers, UV lasers, CO2 lasers In addition, our portfolio includes numerous multiple wavelength and broadband coatings  | 
          ||
| 
                  Max. laser power (standard systems, 100% duty cycle)  | 
              250 W @ 1064 nm | ||
| Typical scan angle | ±0.35 rad (optical) | ||
| 
                  Image field size (1064 nm, f = 160 mm)  | 
              95 mm x 95 mm | ||
| Fiber adapter | no | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Dynamic | |||
| Number of installed tunings | 1 | ||
| Typical tuning | fast vector tuning | ||
| Tracking error | 0.15 ms | ||
| 
                  Marking speed (f = 160 mm)  | 
              2.0 m/s | ||
| 
                  Positioning speed (f = 160 mm)  | 
              14.0 m/s | ||
| 
                    Writing speed (with F-Theta objective, f = 160 mm)  | 
              |||
| High writing quality | 500 cps | ||
| Good writing quality | 740 cps | ||
| 
                    Step response (full angle) (settling to 1/1000 of full scale)  | 
              |||
| 1% of full scale | 0.35 ms | ||
| 10% of full scale | 0.90 ms | ||
| 
                    Step response (fixed angle) (in tolerance band ± 450 μrad)  | 
              |||
| 10 mrad | |||
| 100 mrad | |||
| Precision | |||
| 
                  Repeatability (RMS)  | 
              < 2 µrad | ||
| 
                  Positioning resolution (max.)*  | 
              16 bit * | ||
| Nonlinearity | < 0.9 mrad / 44° | ||
| Temperature drift | |||
| Offset | < 25 µrad/K | ||
| Gain | < 25 ppm/K | ||
| 
                    8 hour drift (after 30 min warm-up)  | 
              |||
| Offset | < 100 µrad | ||
| Gain | < 100 ppm | ||
| 
                    24 hour drift (after 3 h warm-up)  | 
              |||
| Offset | |||
| Gain | |||
| 
                               
              * 16 bit: based on the full angle range (e.g. positioning resolution 11 µrad for angle range ±0.36 rad)
             
                         | 
    |||
| Electrics / Control | |||
| Servo control galvanometer scanner | analog servo control board | ||
| 
                  Control interface (alternatives)  | 
              
            digital SL2-100,  digital XY2-100 standard, analog ±4.8 V  | 
          ||
| Advanced diagnosis options | no | ||
| Power requirements | ±15 V DC, max. 3 A each | ||
| Mechanics | |||
| Scan axes | 2-axis system | ||
| Housing variants | standard: scan head | ||
| Connector positions | beam entrance side | ||
| 
                  Dimensions (L x W x H) (standard housing)  | 
              (133.5 x 99.5 x 105.5) mm3 | ||
| 
                  Weight without objective (standard housing)  | 
              2.3 kg | ||
| Beam displacement | 16.42 mm | ||
| Other Provisions | |||
| Water cooling | no | ||
| Air cooling | no | ||
| Options | objectives with optimized mounting kits | ||
| Other Specifications | |||
| 
                  Dimensions (L x W x H) (standard housing)  | 
              (133.5 x 99.5 x 105.5) mm3 | ||
| 
                  Weight without objective (standard housing)  | 
              2.3 kg | ||
| Beam displacement | 16.42 mm | ||
| Operating temperature | 25 °C ± 10 °C | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Skew | |||
| 
                  Step response time (settling to 1/1000 of full scale)  | 
              |||
| Typical Optical Configurations | |||
| Applications | |||
| Typical Applications | 
            Marking applications,  Materials processing in the semiconductor industry, Microstructuring, Processing-on-the-fly  | 
          ||