| fiberSYS | |||
| Aperture | 30 mm | ||
|
Angle Transmitter of Galvanometer Scanners |
digital encoder | ||
| Optical Configuration | |||
|
Wavelength range (standard) |
1060 - 1085 nm | ||
|
Max. laser power (standard systems, 100% duty cycle) |
2000 W depending on optical configuration |
||
| Typical scan angle | ±0.37 rad (optical) | ||
|
Image field size (1064 nm, f = 160 mm) |
|||
| Fiber adapter | QBH/HLC-8 QD/LLK-D | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Dynamic | |||
| Number of installed tunings | 1 | ||
| Typical tuning | SCANahead | ||
| Tracking error | 0 ms | ||
|
Marking speed (f = 160 mm) |
43.0 m/s (for f = 615 mm) |
||
|
Positioning speed (f = 160 mm) |
43.0 m/s (for f = 615 mm) |
||
|
Writing speed (with F-Theta objective, f = 160 mm) |
|||
| High writing quality | |||
| Good writing quality | |||
|
Step response (full angle) (settling to 1/1000 of full scale) |
|||
| 1% of full scale | 0.47 ms | ||
| 10% of full scale | 1.54 ms | ||
|
Step response (fixed angle) (in tolerance band ± 450 μrad) |
|||
| 10 mrad | |||
| 100 mrad | |||
| Precision | |||
|
Repeatability (RMS) |
< 0.4 µrad | ||
|
Positioning resolution (max.)* |
20 bit * | ||
| Nonlinearity | < 0.5 mrad / 44° | ||
| Temperature drift | |||
| Offset | < 25 µrad/K | ||
| Gain | < 8 ppm/K | ||
|
8 hour drift (after 30 min warm-up) |
|||
| Offset | < 30 µrad | ||
| Gain | < 30 ppm | ||
|
24 hour drift (after 3 h warm-up) |
|||
| Offset | < 30 µrad | ||
| Gain | < 30 ppm | ||
|
* 20 bit: based on the full angle range (e.g. positioning resolution 0.7 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
|
|||
| Electrics / Control | |||
| Servo control galvanometer scanner | digital servo control board | ||
|
Control interface (alternatives) |
digital SL2-100 | ||
| Advanced diagnosis options | yes (iDRIVE) | ||
| Power requirements | 48 V DC, max. 6 A | ||
| Mechanics | |||
| Scan axes | 3-axis system | ||
| Housing variants | scan head | ||
| Connector positions | beam entrance side | ||
|
Dimensions (L x W x H) (standard housing) |
(290 x 140 x 340) mm3 | ||
|
Weight without objective (standard housing) |
20 kg | ||
| Beam displacement | 35.54 mm | ||
| Other Provisions | |||
| Water cooling | yes | ||
| Air cooling | no | ||
| Options |
Open Interface Extension (OIE), additional monitoring port via beam splitter cube |
||
| Other Specifications | |||
|
Dimensions (L x W x H) (standard housing) |
(290 x 140 x 340) mm3 | ||
|
Weight without objective (standard housing) |
20 kg | ||
| Beam displacement | 35.54 mm | ||
| Operating temperature | 25 °C ± 10 °C | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Skew | |||
|
Step response time (settling to 1/1000 of full scale) |
|||
| Typical Optical Configurations | Custemers specific | ||
| Applications | |||
| Typical Applications |
Additive manufacturing, Laser welding, Electromobility, 3D applications |
||