| palmSCAN 6 | |||
| Aperture | 6 mm | ||
|
Angle Transmitter of Galvanometer Scanners |
analog position detector | ||
| Optical Configuration | |||
|
Wavelength range (standard) |
1064 / 532 nm 450 - 2500 nm 9300 - 10600 nm |
||
|
Max. laser power (standard systems, 100% duty cycle) |
60 W @ 1064 nm | ||
| Typical scan angle | ±0.10 rad (opt.) | ||
|
Image field size (1064 nm, f = 160 mm) |
35 mm x 35 mm (for 10600 nm, f = 100 mm) |
||
| Fiber adapter | no | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Dynamic | |||
| Number of installed tunings | 1 | ||
| Typical tuning | |||
| Tracking error | 0.14 ms | ||
|
Marking speed (f = 160 mm) |
|||
|
Positioning speed (f = 160 mm) |
|||
|
Writing speed (with F-Theta objective, f = 160 mm) |
|||
| High writing quality | |||
| Good writing quality | |||
|
Step response (settling to 1/1000 of full scale) |
|||
| 1% of full scale | 0.35 ms | ||
| 10% of full scale | 0.90 ms | ||
| Precision | |||
|
Repeatability (RMS) |
|||
|
Positioning resolution (max.)* |
|||
| Nonlinearity | < 4.2 mrad | ||
| Temperature drift | |||
| Offset | |||
| Gain | |||
|
8 hour drift (after 30 min warm-up) |
|||
| Offset | |||
| Gain | |||
|
24 hour drift (after 3 h warm-up) |
|||
| Offset | |||
| Gain | |||
| Electrics / Control | |||
| Servo control galvanometer scanner | analog servo control board | ||
|
Control interface (alternatives) |
digital XY2-100 standard, analog ±4.8 V, analog ±9.6 V |
||
| Advanced diagnosis options | no | ||
| Power requirements | ±(15+1.5) V DC, max. 0.5 A each | ||
| Mechanics | |||
| Scan axes | 2-axis system | ||
| Housing variants | scan head | ||
| Connector positions | |||
|
Dimensions (L x W x H) (standard housing) |
|||
|
Weight without objective (standard housing) |
approx. 200 g | ||
| Beam displacement | |||
| Other Provisions | |||
| Water cooling | |||
| Air cooling | |||
| Options | optimized mirror sets for various lasers | ||
| Other Specifications | |||
|
Dimensions (L x W x H) (standard housing) |
|||
|
Weight without objective (standard housing) |
approx. 200 g | ||
| Beam displacement | |||
| Operating temperature | 25 °C ± 10 °C | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Skew | |||
|
Step response time (settling to 1/1000 of full scale) |
|||
| Typical Optical Configurations | |||
| Applications | |||
| Typical Applications |
Wrinkle reduction, Tattoo removement, Hair removal, Vascular treatment |
||