| powerSCAN II 70i | |||
| Aperture | 70 mm | ||
|
Angle Transmitter of Galvanometer Scanners |
analog position detector | ||
| Optical Configuration | |||
|
Wavelength range (standard) |
9400 nm, 10600 nm | ||
|
Max. laser power (standard systems, 100% duty cycle) |
2500 W @ 9400 nm, 10600 nm | ||
| Typical scan angle | ±0.35 rad (opt.) | ||
|
Image field size (1064 nm, f = 160 mm) |
|||
| Fiber adapter | no | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Dynamic | |||
| Number of installed tunings | 1 | ||
| Typical tuning | fast vector tuning | ||
| Tracking error | 1.6 ms | ||
|
Marking speed (f = 160 mm) |
|||
|
Positioning speed (f = 160 mm) |
27 rad/s | ||
|
Writing speed (with F-Theta objective, f = 160 mm) |
|||
| High writing quality | |||
| Good writing quality | |||
|
Step response (settling to 1/1000 of full scale) |
|||
| 1% of full scale | 3.5 ms | ||
| 10% of full scale | 6.5 ms | ||
| Precision | |||
|
Repeatability (RMS) |
< 4 µrad | ||
|
Positioning resolution (max.)* |
18 bit for XY, 16 bit for Z* | ||
| Nonlinearity | < 2.1 mrad / 44° | ||
| Temperature drift | |||
| Offset | |||
| Gain | |||
|
8 hour drift (after 30 min warm-up) |
|||
| Offset | < 50 µrad | ||
| Gain | < 50 ppm | ||
|
24 hour drift (after 3 h warm-up) |
|||
| Offset | |||
| Gain | |||
|
* 18 bit: based on the full angle range (e.g. positioning resolution 2.8 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
|
|||
| Electrics / Control | |||
| Servo control galvanometer scanner | digital servo control board | ||
|
Control interface (alternatives) |
digital SL2-100 | ||
| Advanced diagnosis options | yes (iDRIVE) | ||
| Power requirements |
(48+1.5) V DC, max. 10 A each (20 A peak current) |
||
| Mechanics | |||
| Scan axes | 3-axis system with integrated varioSCAN | ||
| Housing variants | scan head | ||
| Connector positions | opposite to beam exit side | ||
|
Dimensions (L x W x H) (standard housing) |
(475 x 283 x 305) mm3 (with varioSCAN) |
||
|
Weight without objective (standard housing) |
37 kg | ||
| Beam displacement | 97.53 mm | ||
| Other Provisions | |||
| Water cooling | yes | ||
| Air cooling | yes | ||
| Options | |||
| Other Specifications | |||
|
Dimensions (L x W x H) (standard housing) |
(475 x 283 x 305) mm3 (with varioSCAN) |
||
|
Weight without objective (standard housing) |
37 kg | ||
| Beam displacement | 97.53 mm | ||
| Operating temperature | 25 °C ± 10 °C | ||
| Gain error | < 5 mrad | ||
| Zero offset deviation | < 5 mrad | ||
| Skew | < 1.5 mrad | ||
|
Step response time (settling to 1/1000 of full scale) |
|||
| Typical Optical Configurations | with varioSCAN 80 | ||
| Applications | |||
| Typical Applications |
Laser cutting, Rapid Manufacturing, 3D applications, Processing-on-the-fly |
||