powerSCAN II 50i | |||
Aperture | 50 mm | ||
Angle Transmitter of Galvanometer Scanners |
analog position detector | ||
Optical Configuration | |||
Wavelength range (standard) |
9400 - 10600 nm | ||
Max. laser power (standard systems, 100% duty cycle) |
4000 W @ 10600 nm | ||
Typical scan angle | ±0.35 rad (opt.) | ||
Image field size (1064 nm, f = 160 mm) |
|||
Fiber adapter | no | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Dynamic | |||
Number of installed tunings | 1 | ||
Typical tuning | fast vector tuning | ||
Tracking error | < 0.45 ms | ||
Marking speed (f = 160 mm) |
|||
Positioning speed (f = 160 mm) |
20 rad/s | ||
Writing speed (with F-Theta objective, f = 160 mm) |
|||
High writing quality | |||
Good writing quality | |||
Step response (settling to 1/1000 of full scale) |
|||
1% of full scale | 1.0 ms | ||
10% of full scale | 4.5 ms | ||
Precision | |||
Repeatability (RMS) |
< 4 µrad | ||
Positioning resolution (max.)* |
18 bit for XY, 16 bit for Z* | ||
Nonlinearity | < 2.1 mrad / 44° | ||
Temperature drift | |||
Offset | |||
Gain | |||
8 hour drift (after 30 min warm-up) |
|||
Offset | < 50 µrad | ||
Gain | < 50 ppm | ||
24 hour drift (after 3 h warm-up) |
|||
Offset | |||
Gain | |||
* 18 bit: based on the full angle range (e.g. positioning resolution 2.8 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
|
|||
Electrics / Control | |||
Servo control galvanometer scanner | digital servo control board | ||
Control interface (alternatives) |
digital SL2-100 | ||
Advanced diagnosis options | yes (iDRIVE) | ||
Power requirements |
(48+1.5) V DC, max. 10 A each (20 A peak current) |
||
Mechanics | |||
Scan axes | 3-axis system with integrated varioSCAN | ||
Housing variants | scan head | ||
Connector positions | opposite to beam exit side | ||
Dimensions (L x W x H) (standard housing) |
(433 x 268 x 266) mm3 (with varioSCAN) |
||
Weight without objective (standard housing) |
35 kg | ||
Beam displacement | 72.72 mm | ||
Other Provisions | |||
Water cooling | yes | ||
Air cooling | yes | ||
Options | |||
Other Specifications | |||
Dimensions (L x W x H) (standard housing) |
(433 x 268 x 266) mm3 (with varioSCAN) |
||
Weight without objective (standard housing) |
35 kg | ||
Beam displacement | 72.72 mm | ||
Operating temperature | 25 °C ± 10 °C | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Skew | < 1.5 mrad | ||
Step response time (settling to 1/1000 of full scale) |
|||
Typical Optical Configurations | with varioSCAN 60 | ||
Applications | |||
Typical Applications |
Laser cutting, Rapid Manufacturing, 3D applications, Processing-on-the-fly |
||